Precison Gas Analyzer - 350
Precison Gas Analyzer - 350
Regular price
$1,000.00 CAD
Regular price
$1,300.00 CAD
Sale price
$1,000.00 CAD
Unit price
/
per
Highlights -
- Flue gas analysis with up to 6 customizable gas sensors, changeable on-site by the user.
- Extended measurement range for accurate readings even at high gas concentrations.
- User-friendly, easy-to-change gas sensors and access to replaceable parts.
- Sealed, impact-protected housing for durability in harsh environments.
- Simple operation via Control Unit or easyEmission software (sold separately).
- Removable operating and display unit, connectable via Bluetooth or data bus cable.
Technical Data -
Temperature - NTC | |
Measuring range
|
-20 to +50 °C
|
Accuracy |
±0.2 °C (-10 to +50 °C)
|
Resolution |
0.1 °C (-20 to +50 °C)
|
Ambient temperature probe | |
Temperature - TC Type K (NiCr-Ni) | |
Measuring range
|
-200 to +1370 °C
|
Accuracy |
±1 °C (-200 to -100.1 °C)
|
±1 °C (200.1 to +1370 °C)
|
|
±0.4 °C (-100 to +200 °C)
|
|
Resolution |
0.1 °C (-200 to +1370 °C)
|
Temperature - TC Type S (Pt10Rh-Pt) | |
Measuring range
|
0 to +1760 °C
|
Accuracy |
±1 °C (0 to +1760 °C)
|
Resolution |
0.1 °C (0 to +1760 °C)
|
Differential Pressure - Piezoresistive | |
Measuring range
|
-200 to +200 hPa
|
-40 to +40 hPa
|
|
Accuracy |
±1.5 % of mv (+3 to +40 hPa)
|
±0.5 hPa (-49.9 to +49.9 hPa)
|
|
±1.5 % of mv (-200 to -50 hPa)
|
|
±0.03 hPa (-2.99 to +2.99 hPa)
|
|
±1.5 % of mv (-40 to -3 hPa)
|
|
±1.5 % of mv (+50 to +200 hPa)
|
|
Resolution |
0.01 hPa (-40 to +40 hPa)
|
0.1 hPa (-200 to +200 hPa)
|
|
Absolute Pressure | |
Measuring range
|
600 to +1150 hPa
|
Accuracy |
±10 hPa
|
Resolution |
1 hPa
|
Flue gas O₂ | |
Measuring range
|
0 to +25 Vol.%
|
Accuracy |
±0.8% of fsv (0 to +25 Vol.%)
|
Resolution |
0.01 Vol.% (0 to +25 Vol.%)
|
Reaction time t₉₀ |
20 s (t₉₅)
|
Flue gas CO (with H₂-compensation) | |
Measuring range
|
0 to +10000 ppm
|
Accuracy |
±10 ppm (0 to +199 ppm)
|
±5 % of mv (+200 to +2000 ppm)
|
|
±10 % of mv (+2001 to +10000 ppm)
|
|
Resolution |
1 ppm (0 to +10000 ppm)
|
Reaction time t₉₀ |
40 s
|
H₂ only as an indicator | |
Flue gas COlow (with H₂-compensation) | |
Measuring range
|
0 to 500 ppm
|
Accuracy |
±5 % of mv (+40 to +500 ppm)
|
±2 ppm (0 to +39.9 ppm)
|
|
Resolution |
0.1 ppm (0 to +500 ppm)
|
Reaction time t₉₀ |
40 s
|
H₂ only as an indicator | |
Flue gas NO | |
Measuring range
|
0 to +4000 ppm
|
Accuracy |
±5 % of mv (+100 to +1999 ppm)
|
±10 % of mv (+2000 to +4000 ppm)
|
|
±5 ppm (0 to +99 ppm)
|
|
Resolution |
1 ppm (0 to +4000 ppm)
|
Reaction time t₉₀ |
30 s
|
Flue gas Nolow | |
Measuring range
|
0 to +300 ppm
|
Accuracy |
±5 % of mv (+40 to +300 ppm)
|
±2 ppm (0 to +39.9 ppm)
|
|
Resolution |
±0.1 ppm (0 to +300 ppm)
|
Reaction time t₉₀ |
30 s
|
Flue gas NO₂ | |
Measuring range
|
0 to +500 ppm
|
Accuracy |
±5 % of mv (+100 to +500 ppm)
|
±5 ppm (0 to +99.9 ppm)
|
|
Resolution |
0.1 ppm (0 to +500 ppm)
|
Reaction time t₉₀ |
40 s
|
Flue gas SO₂ | |
Measuring range
|
0 to +5000 ppm
|
Accuracy |
±10 % of mv (+2001 to +5000 ppm)
|
±5 % of mv (+100 to +2000 ppm)
|
|
±5 ppm (0 to +99 ppm)
|
|
Resolution |
1 ppm (0 to +5000 ppm)
|
Reaction time t₉₀ |
30 s
|
Flue gas degree of effectivity, Eta (calculated) | |
Measuring range
|
0 to +120 %
|
Resolution |
0.1 % (0 to +120 %)
|
Flue gas loss (calculated) | |
Measuring range
|
0 to +99.9 %
|
Resolution |
0.1 % (0 to +99.9 %)
|
Flue gas dewpoint (calculated) | |
Measuring range
|
0 to +99.9 °Ctd
|
Resolution |
0.1 °Ctd (0 to +99.9 °Ctd)
|
Flue gas CO₂ calculation (calculated from O₂) | |
Measuring range
|
0 to CO₂ max
|
Accuracy |
calculated from O₂ ±0.2 Vol.%
|
Resolution |
0.01 Vol.%
|
Flue gas H₂S | |
Measuring range
|
0 to +300 ppm
|
Accuracy |
±5 % of mv (+40 to +300 ppm)
|
±2 ppm (0 to +39.9 ppm)
|
|
Resolution |
0.1 ppm (0 to +300 ppm)
|
Reaction time t₉₀ |
35 s
|
Flue gas CO₂ - NDIR | |
Measuring range
|
0 to +50 Vol.%
|
Accuracy |
±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%)
|
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)
|
|
Resolution |
0.01 Vol.% (0 to 25 Vol.%)
|
0.1 Vol.% (> 25 Vol.%)
|
|
Reaction time t₉₀ |
10 s
|
Velocity / Volume flow | |
Measuring range
|
0 to +40 m/s
|
Resolution |
0.1 m/s (0 to +40 m/s)
|
Methane (CH₄) | |
Measuring range
|
100 to 40000 ppm
|
Accuracy |
< 400 ppm (100 to 4000 ppm)
|
< 10 % of mv (> 4000 ppm)
|
|
Resolution |
10 ppm
|
Min. O₂ requirement in flue gas |
2 % + (2 x mV methane)
|
Reaction time t₉₀ |
< 40 s
|
Response factor |
1
|
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user. | |
Propane (C₃H₈) | |
Measuring range
|
100 to 21000 ppm
|
Accuracy |
< 400 ppm (100 to 4000 ppm)
|
< 10 % of mv (> 4000 ppm)
|
|
Resolution |
10 ppm
|
Min. O₂ requirement in flue gas |
2 % + (5 x mV propane)
|
Reaction time t₉₀ |
< 40 s
|
Response factor |
1.5
|
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user. | |
Butane (C₄H₁₀) | |
Measuring range
|
100 to 18000 ppm
|
Accuracy |
< 400 ppm (100 to 4000 ppm)
|
< 10 % of mv (> 4000 ppm)
|
|
Resolution |
10 ppm
|
Min. O₂ requirement in flue gas |
2 % + (6.5 x mV butane)
|
Reaction time t₉₀ |
< 40 s
|
Response factor |
2
|
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user. | |
Flue gas SO₂ low | |
Measuring range
|
0 to 200 ppm
|
Accuracy |
±5 (40 to 200 ppm)
|
±2 ppm (0 to 39.9 ppm)
|
|
Resolution |
0.1 ppm
|
Reaction time t₉₀ |
30 s
|
In combination with the special SO2low gas sampling probe 0563 1251 or the industrial heated probe kit 0600 7630 | |
General technical data | |
Weight
|
4800 g
|
Dimensions |
330 x 128 x 438 mm
|
Operating temperature |
-5 to +45 °C
|
Product-/housing material |
ABS
|
Protection class |
IP40
|
Connectable probes |
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure
|
Product colour |
Black
|
Battery life |
5 h
|
Battery type |
lithium batteries
|
DC electric tension input |
11V to 40V
|
Power supply |
AC mains unit 100V to 240V (50 to 60 Hz)
|
Dewpoint calculation |
0 °Ctd; 99 °Ctd
|
Hose length |
16.2 m (corresponds to 5 probe hose extensions)
|
Max. dust load |
20 g/m³ dust in flue gas
|
Max. humidity load |
70 °C dewpoint temperature
|
Max. neg. press./flue gas |
-300 mbar
|
Max. pos. press./flue gas |
50 mbar
|
Pump flow |
1 l/min. with through-flow monitoring
|
Trigger input |
Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA
|
Maximum memory |
250,000 readings
|
Interface |
data bus; Bluetooth®; USB; IR/IRDA interface; Mains connection; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; dilution gas inlet for measurement range extension
|
Storage temperature |
-20 to +50 °C
|
Share
- Description
Description
Highlights -
Technical Data -
- Flue gas analysis with up to 6 customizable gas sensors, changeable on-site by the user.
- Extended measurement range for accurate readings even at high gas concentrations.
- User-friendly, easy-to-change gas sensors and access to replaceable parts.
- Sealed, impact-protected housing for durability in harsh environments.
- Simple operation via Control Unit or easyEmission software (sold separately).
- Removable operating and display unit, connectable via Bluetooth or data bus cable.
Technical Data -
Temperature - NTC | |
Measuring range | -20 to +50 °C |
Accuracy | ±0.2 °C (-10 to +50 °C) |
Resolution | 0.1 °C (-20 to +50 °C) |
Ambient temperature probe | |
Temperature - TC Type K (NiCr-Ni) | |
Measuring range | -200 to +1370 °C |
Accuracy | ±1 °C (-200 to -100.1 °C) |
±1 °C (200.1 to +1370 °C) | |
±0.4 °C (-100 to +200 °C) | |
Resolution | 0.1 °C (-200 to +1370 °C) |
Temperature - TC Type S (Pt10Rh-Pt) | |
Measuring range | 0 to +1760 °C |
Accuracy | ±1 °C (0 to +1760 °C) |
Resolution | 0.1 °C (0 to +1760 °C) |
Differential Pressure - Piezoresistive | |
Measuring range | -200 to +200 hPa |
-40 to +40 hPa | |
Accuracy | ±1.5 % of mv (+3 to +40 hPa) |
±0.5 hPa (-49.9 to +49.9 hPa) | |
±1.5 % of mv (-200 to -50 hPa) | |
±0.03 hPa (-2.99 to +2.99 hPa) | |
±1.5 % of mv (-40 to -3 hPa) | |
±1.5 % of mv (+50 to +200 hPa) | |
Resolution | 0.01 hPa (-40 to +40 hPa) |
0.1 hPa (-200 to +200 hPa) | |
Absolute Pressure | |
Measuring range | 600 to +1150 hPa |
Accuracy | ±10 hPa |
Resolution | 1 hPa |
Flue gas O₂ | |
Measuring range | 0 to +25 Vol.% |
Accuracy | ±0.8% of fsv (0 to +25 Vol.%) |
Resolution | 0.01 Vol.% (0 to +25 Vol.%) |
Reaction time t₉₀ | 20 s (t₉₅) |
Flue gas CO (with H₂-compensation) | |
Measuring range | 0 to +10000 ppm |
Accuracy | ±10 ppm (0 to +199 ppm) |
±5 % of mv (+200 to +2000 ppm) | |
±10 % of mv (+2001 to +10000 ppm) | |
Resolution | 1 ppm (0 to +10000 ppm) |
Reaction time t₉₀ | 40 s |
H₂ only as an indicator | |
Flue gas COlow (with H₂-compensation) | |
Measuring range | 0 to 500 ppm |
Accuracy | ±5 % of mv (+40 to +500 ppm) |
±2 ppm (0 to +39.9 ppm) | |
Resolution | 0.1 ppm (0 to +500 ppm) |
Reaction time t₉₀ | 40 s |
H₂ only as an indicator | |
Flue gas NO | |
Measuring range | 0 to +4000 ppm |
Accuracy | ±5 % of mv (+100 to +1999 ppm) |
±10 % of mv (+2000 to +4000 ppm) | |
±5 ppm (0 to +99 ppm) | |
Resolution | 1 ppm (0 to +4000 ppm) |
Reaction time t₉₀ | 30 s |
Flue gas Nolow | |
Measuring range | 0 to +300 ppm |
Accuracy | ±5 % of mv (+40 to +300 ppm) |
±2 ppm (0 to +39.9 ppm) | |
Resolution | ±0.1 ppm (0 to +300 ppm) |
Reaction time t₉₀ | 30 s |
Flue gas NO₂ | |
Measuring range | 0 to +500 ppm |
Accuracy | ±5 % of mv (+100 to +500 ppm) |
±5 ppm (0 to +99.9 ppm) | |
Resolution | 0.1 ppm (0 to +500 ppm) |
Reaction time t₉₀ | 40 s |
Flue gas SO₂ | |
Measuring range | 0 to +5000 ppm |
Accuracy | ±10 % of mv (+2001 to +5000 ppm) |
±5 % of mv (+100 to +2000 ppm) | |
±5 ppm (0 to +99 ppm) | |
Resolution | 1 ppm (0 to +5000 ppm) |
Reaction time t₉₀ | 30 s |
Flue gas degree of effectivity, Eta (calculated) | |
Measuring range | 0 to +120 % |
Resolution | 0.1 % (0 to +120 %) |
Flue gas loss (calculated) | |
Measuring range | 0 to +99.9 % |
Resolution | 0.1 % (0 to +99.9 %) |
Flue gas dewpoint (calculated) | |
Measuring range | 0 to +99.9 °Ctd |
Resolution | 0.1 °Ctd (0 to +99.9 °Ctd) |
Flue gas CO₂ calculation (calculated from O₂) | |
Measuring range | 0 to CO₂ max |
Accuracy | calculated from O₂ ±0.2 Vol.% |
Resolution | 0.01 Vol.% |
Flue gas H₂S | |
Measuring range | 0 to +300 ppm |
Accuracy | ±5 % of mv (+40 to +300 ppm) |
±2 ppm (0 to +39.9 ppm) | |
Resolution | 0.1 ppm (0 to +300 ppm) |
Reaction time t₉₀ | 35 s |
Flue gas CO₂ - NDIR | |
Measuring range | 0 to +50 Vol.% |
Accuracy | ±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%) |
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%) | |
Resolution | 0.01 Vol.% (0 to 25 Vol.%) |
0.1 Vol.% (> 25 Vol.%) | |
Reaction time t₉₀ | 10 s |
Velocity / Volume flow | |
Measuring range | 0 to +40 m/s |
Resolution | 0.1 m/s (0 to +40 m/s) |
Methane (CH₄) | |
Measuring range | 100 to 40000 ppm |
Accuracy | < 400 ppm (100 to 4000 ppm) |
< 10 % of mv (> 4000 ppm) | |
Resolution | 10 ppm |
Min. O₂ requirement in flue gas | 2 % + (2 x mV methane) |
Reaction time t₉₀ | < 40 s |
Response factor | 1 |
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user. | |
Propane (C₃H₈) | |
Measuring range | 100 to 21000 ppm |
Accuracy | < 400 ppm (100 to 4000 ppm) |
< 10 % of mv (> 4000 ppm) | |
Resolution | 10 ppm |
Min. O₂ requirement in flue gas | 2 % + (5 x mV propane) |
Reaction time t₉₀ | < 40 s |
Response factor | 1.5 |
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user. | |
Butane (C₄H₁₀) | |
Measuring range | 100 to 18000 ppm |
Accuracy | < 400 ppm (100 to 4000 ppm) |
< 10 % of mv (> 4000 ppm) | |
Resolution | 10 ppm |
Min. O₂ requirement in flue gas | 2 % + (6.5 x mV butane) |
Reaction time t₉₀ | < 40 s |
Response factor | 2 |
Lower explosion limit (LEL) must be adhered to. The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user. | |
Flue gas SO₂ low | |
Measuring range | 0 to 200 ppm |
Accuracy | ±5 (40 to 200 ppm) |
±2 ppm (0 to 39.9 ppm) | |
Resolution | 0.1 ppm |
Reaction time t₉₀ | 30 s |
In combination with the special SO2low gas sampling probe 0563 1251 or the industrial heated probe kit 0600 7630 | |
General technical data | |
Weight | 4800 g |
Dimensions | 330 x 128 x 438 mm |
Operating temperature | -5 to +45 °C |
Product-/housing material | ABS |
Protection class | IP40 |
Connectable probes | 1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure |
Product colour | Black |
Battery life | 5 h |
Battery type | lithium batteries |
DC electric tension input | 11V to 40V |
Power supply | AC mains unit 100V to 240V (50 to 60 Hz) |
Dewpoint calculation | 0 °Ctd; 99 °Ctd |
Hose length | 16.2 m (corresponds to 5 probe hose extensions) |
Max. dust load | 20 g/m³ dust in flue gas |
Max. humidity load | 70 °C dewpoint temperature |
Max. neg. press./flue gas | -300 mbar |
Max. pos. press./flue gas | 50 mbar |
Pump flow | 1 l/min. with through-flow monitoring |
Trigger input | Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA |
Maximum memory | 250,000 readings |
Interface | data bus; Bluetooth®; USB; IR/IRDA interface; Mains connection; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; dilution gas inlet for measurement range extension |
Storage temperature | -20 to +50 °C |